Dual-Zone PIR's combine a horizontal and downward curtain requiring simultaneous activation for alarm.
With up to 12m x 180˚ range these sensors are perfect for use in both domestic and industrial applications.
SPECIFICATIONS |
|
Detection system |
Passive infrared
|
Coverage |
Horizontal: +/-90° Detection distance: 6.6' to 40' (2 to 12m) (By adjusting vertical angle of downward zone)
x2
|
Sensitive zone |
Horizontal zone: 7 zones Downward zone: 7 zones
x2
|
Mounting height |
0.8 - 1.2m
|
Area adjustment |
Horizontal: +/-90° Detection distance: 6.6' to 40' (2 to 12m) (By adjusting vertical angle of downward zone)
|
Supply voltage |
12 to 30V DC (non-polarity)
|
Current consumption |
40mA MAX.
|
Alarm output |
Dry contact relay output N.C./N.O. selectable Contact capacity: 30V (AC/DC), 0.25A MAX. (Resistive load) Contact operation: Detection time + off delay
|
Tamper output |
Dry contact relay output N/C Contact capacity: 30V (AC/DC), 0.1A MAX. (Resistive load)
|
LED indicator |
Red LED: Blinking at warming up (LED disabled) Lighting at alarm (LED disabled)
|
Pulse count |
Once / three times (with a switch)
|
Sensitivity adjustment |
Approx. 30% (L) - Approx. 170% (H) (By potentiometer)
|
Detection mode |
AND / OR selectable
|
Mounting position |
Indoor / Outdoor
|
Wiring |
Terminals
|
Weight |
16.5oz (470g)
|
Appearance |
Body: AES resin Lens: PE resin
|
Accessory |
Tapping screw: 2 Area masking sheet: 2
|
ENVIRONMENTAL SPECIFICATION |
|
Ambient temperature |
-4°F to +122°F (-20°C to +50°C)
|