AJAX FIRE PROTECT 2 HEAT/SMOKE/CO - WHITE

Accuracy through steam, dust, and time

FireProtect 2 is a next-gen detector designed for residential fire safety. The unique smoke chamber does not require regular cleaning, the dual-spectrum sensor distinguishes smoke from steam, the thermistor quickly reacts to the synthetic materials burning, and sophisticated software minimizes false alarms. Thought-out design, mounting, and in-app settings make installation straightforward and quick. Everything meets the most modern fire safety standards.

Patented smoke chamber technology

Encouraged by world standards and best practices, Ajax reaches an entirely new level of technology in residential fire safety with FireProtect 2. A unique smoke chamber that is dustproof and impenetrable for insects, a dual-spectrum optical sensor, and a proprietary HazeFlow 2 software algorithm guarantee the speed and accuracy of fire detection — ultimate safety with no stress about false alarms.

Impenetrable for dust and insects

The smoke chamber is designed with zero possibility of contamination that can affect detection. A unique circulation mechanism provides the optical sensor with an unobstructed field to quickly identify products of combustion in the air.

Ignores сooking fumes and water steam

The smoke chamber is hardwired with a dual-spectrum optical sensor that has blue and infrared LEDs with different wavelengths. It uses the most reliable real-time detection method, directly measuring the microparticle concentration in the air. This technology allows FireProtect 2 to determine the size of the volatile particles inside the chamber and respond only to smoke, ignoring vapour and water steam.

Only real threats considered

In-depth research on materials combustion resulted in HazeFlow 2 — a smoke detection algorithm developed by Ajax. The algorithm contemporaneously analyses and compares data from the dual-spectrum optical sensor to a specified pattern to define smoke from vapour or steam. The detector instantly raises the alarm when pattern dynamics indicate a real case of fire.

Protects from invisible danger

Carbon monoxide (CO) is colorless, odorless, and otherwise imperceptible without a carbon monoxide detector, so poisoning can occur unnoticed. Even low concentrations can be enough to have a negative health impact, especially on those with chronic illnesses, pregnant, the elderly, and young children. High-level exposure can cause permanent damage or even death in a very short period of time. FireProtect 2 warns about a dangerous CO concentration at the level of 50 ppm before even the first signs of poisoning occur. A built-in chemical sensor is responsive to low concentrations and can accurately detect the CO level straight up to 10 years.

CO alarm

  • 50 ppm in no more than 90 minutes
  • 100 ppm in no more than 40 minutes
  • 300 ppm in no more than 3 minutes

Even when it's fire without smoke

FireProtect 2 is equipped with two class A1R thermistors to detect smokeless fire threats. They give a significant advantage in detecting a rapid temperature rise when synthetic materials burn, or a fire starts from smoldering. Thermistors are located outside the enclosure to eliminate life-saving detection delays. So FireProtect 2 is ready to detect a fire as fast as possible, even if it starts imperceptibly.

Heat alarm

  • 10°C increase in temperature within a minute
  • Exceeding +64°C

Stable performance for a decade

Cutting-edge engineering of hardware and software allowed us to implement advanced capabilities and offer autonomy in the size of the compact smart detector. FireProtect 2 complies with strict residential fire safety standards with long-lasting battery life while featuring constant data exchange with a hub and real-time analysis system to filter false alarms. The detector is available in two versions with different battery options to cover every market need.

 

Low battery warning

The detector reports low batteries at least 30 days before its full discharge. Installers and users get notifications from their Ajax apps. Also, FireProtect 2 has an LED indicator and audible beeps for a low battery alert.


In-app notification


Audible indication


LED indication

Always informed, everywhere

For residential fire alarm systems, informing people about fire danger is the priority. FireProtect 2 is equipped with a powerful 85 dB siren to eliminate the risk of missing an alarm. The detector uses impossible-to-ignore tones with different patterns to indicate an alarm or event, so it’s easy to recognize the type of threat and react accordingly.

Different sound and LED indications


  • Smoke or heat alarms


  • Dangerous CO level


  • Malfunction


  • Low battery level


  • End of life

Wireless interconnection

All FireProtect 2 detectors can synchronously notify about the fire. As soon as one of them detects a threat, it only takes 20 seconds for the sirens of other fire detectors at the facility to activate. If the fire occurs at night, the volume of 85 dB can wake up even a deep sleeper.

Full monitoring for the building

The system instantly notifies about alarms with the critical alerts from the Ajax apps. Security companies and users know exactly which device triggered, when and where it happened. The system controls each device state and reports if there is a malfunction or it's time to replace the batteries.

The event log records 500 recent events within the system. The data is explicit with the device, time, and description of the event. It helps reconstruct the actual event and find the causes to obtain comprehensive information for firefighters or an insurance company.

Monitoring with PRO Desktop

With PRO DESKTOP building administration staff can observe not only security but Ajax fire detectors for instant reaction to alarms. Device statuses, event log, batteries data — the CMS operator has a complete picture in one intuitive interface, all informative and centralized. The installation engineer can remotely change the settings and provide services in time.

Advanced automation for greater safety

Ajax fire detectors are a part of the Ajax ecosystem and can interact with automation devices and PhOD detectors of the MotionCam lineup through scenarios. In the case of a fire alarm, the WallSwitch relay de-energizes the house, and Relay activates emergency lights. At the same time, MotionCam (PhOD) sends pictures into Ajax apps to identify the cause of the alarm. The result is a reliable combination of security and automation that works as a Swiss watch.

Fire detected

2

FireProtect 2

3

MotionCam (PhOD)

4

Cause of fire

Unique wireless technologies

The Ajax system uses two-way secure radio communication based on the Jeweller proprietary protocol. It supports block cipher encryption and device authentication on every session with the hub to prevent sabotage, spoofing, or data theft.

Ajax wireless technology has up to 1,700 meters of radio signal communication range in an open space, making it on average longer than competing solutions from different manufacturers. Automatic power adjustment makes it energy efficient by not using the maximum power of radio transmitters in system devices on a regular basis. It is also more stable, using less noisy radio frequencies. Ajax hubs use radio hopping to protect against radio interference and signal interception. The system automatically changes frequency within a band and notifies the security company and users about the jamming.


  • Up to 1,700 meters of radio communication with a hub


  • Encrypted two-way radio communication


  • Notifications about jamming and connection loss

     

Scaled and comprehensive

For complex radio signal conditions like large houses with thick walls or warehouses with several buildings, there is the ReX range extender. It boosts the range of all Ajax devices and manages their communication with the hub via Jeweller. And ReX 2 assures stable communication even through steel and concrete via Ethernet using the wire as the additional communication channel. Up to 5 range extenders can operate within one Ajax system to expand the network twice as big, covering underground parking, basements, and metal hangars.


  • Up to 5 range extenders within one system


  • Ethernet as an alternative communication channel

Effortless installation and maintenance

FireProtect 2 is ready to operate straight out of the box. There is no need to disassemble the detector during installation. With an improved SmartBracket panel, an installer can effortlessly fix the detector on ceilings and level it at 90° angles after mounting. The Ajax apps help quickly make the device a part of the system. And it can always be reconfigured remotely without site visits.

Equipped with unique dustproof technology, the maintenance-free smoke chamber does not require regular clean-ups. A self-test system automatically diagnoses sensors and reports their state to the hub. Testing can also be run manually anytime in the app or by pressing the detectors' front panel with any suitable item, either a hand or a mop handle.

SPECS:

Compatibility

Hubs

* with firmware version OS Malevich 2.15.4 or higher

Radio signal range extenders


Communication

Jeweller communication technology

Proprietary wireless technology for transmission of alarms and events.
Features:
  • Two-way communication.
  • Protection against device spoofing.
  • Block encryption featuring a floating key.
  • Instant notifications.
  • Remote configuration via the Ajax apps.

Radio frequency bands

866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the region of sale.

Maximum effective radiated power (ERP)

up to 20 mW
Automatic power control to reduce power consumption and radio interference.

Radio signal modulation

GFSK

Radio communication range

up to 1,700 m
Between the detector and a hub (or radio signal range extender) in an open space.

Encryption of radio communication

All the data stored and transmitted are protected by block encryption with a floating key.

Radio frequency hopping

To prevent radio interference and jamming.

Sensitive elements

smoke sensor
heat sensor
CO (carbon monoxide) sensor

Smoke detection

Sensitive element

double-spectrum optical sensor
Recognizes smoke by the size of particles in the air.

Protection from false alarms

Does not react to water vapor.

Patented smoke chamber

Protects the smoke sensor from dust, dirt, and insects.

Dangerous temperature detection

Sensitive element

according to the requirements for Class A1R heat detectors
Requirements of EN 54-5 and BS 5446-2 standards.

High temperature alarm

at temperatures above 64°C

Temperature spike alarm

when the temperature rises more than 10°C in 1 minute or less

Carbon monoxide (CO) detection

Sensitive element

chemical CO sensor

Alarm if accumulated dose of CO is exceeded

more than 50 ppm (0.005%) — no more than in 90 minutes
more than 100 ppm (0.01%) — no more than in 40 minutes
more than 300 ppm (0.03%) — no more than in 3 minutes
CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute.

Sensor life

10 years
After 10 years of operation, the detector must be replaced with a new one.

Additional features

In-built siren

volume 85 dB at a distance of 3 meters
Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.

Interconnected Fire Detectors Alarms

All fire detectors in the system turn on built-in sirens if at least one of the detectors registers an alarm. An interconnected fire alarm is activated during one “hub — detector” polling interval but no more than 20 seconds later.

LED indication

green is a power indication
A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291.
yellow is an indication of malfunctions
A LED indicator on the device enclosure lights up when malfunctions are detected. For example, in the case of discharged batteries, contamination of the smoke chamber, or end of the service life.
red is an indication of fire alarms
A LED indicator on the device enclosure lights up when the detector registers a fire alarm.

Button on the front panel of the detector

In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.

Recommendations

The device is designed only for indoor installation. SmartBracket mounting panel allows adjusting the position of the detector after installation.

Anti-sabotage protection

Tampering alarm

Alerts of attempts to detach the detector from the surface or remove the mounting panel.

Protection against spoofing

device authentication

Detection of communication failure

within 15 minutes
The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds.

Power supply

For FireProtect 2 RB (Heat/Smoke/CO)

2 × CR123A battery
Up to 7 years of battery life.

Enclosure

Dimensions

124 × 124 × 45 mm

Weight

274.5 g

Operating temperature range

from 0°С to +50°С

Operating humidity

up to 80%

Protection class

IP20

Colours

Black
White

Complete set

FireProtect 2 RB (Heat/Smoke/CO) Jeweller
Smart Bracket mounting panel
Installation kit
2 × CR123A battery (pre-installed)
Quick Start Guide
AJAX FIRE PROTECT 2 HEAT/SMOKE/CO - WHITE - NeonSales South Africa
AJAX FIRE PROTECT 2 HEAT/SMOKE/CO - WHITE
local_offer

Recommended for you

Recently viewed

Recently viewed